Compatibility Matrix

Supporting Hexagon's Asset Lifecycle Intelligence Division
View the ALI Product Lifecycle Document
Home Reports Product Versions

Smart P&ID / SmartPlant P&ID

06.00.00.32 (2009)
January 2009

13/Dec/2025 05:50:00 AM UTC

Enterprise Database Server


Operating Systems
  • Windows 2003 32-bit
    - SP2
  • Windows 2003 R2 32-bit
    - SP2
  • Windows 2003 R2 64-bit
    -  SP2
Database Platforms
  • MS SQL Server 2005 32-bit
    - MDAC 2.8 required for MSSQL 2005 databases. Connected Workshare functionality not supported if using MSSQL.
  • MS SQL Server 2005 64-bit
    - MDAC 2.8 required for MSSQL 2005 databases. Connected Workshare functionality not supported if using MSSQL.
  • Oracle 10g R2 32-bit (10.2)
    - Requires 10.2.0.4
  • Oracle 10g R2 64-bit (10.2)
    - Requires 10.2.0.4

Remote Client Technology


Operating Systems
  • Windows 2003 32-bit
    - SP2
  • Windows 2003 R2 32-bit
    - SP2
  • Windows 2003 R2 64-bit
    - SP2
Database Platforms
  • Microsoft SQL Server 2005 Client
    - MS SQL Client not required for clients only running SPP&ID. If installed, SP2 - MDAC 2.8 required for MSSQL 2005 databases.
  • Oracle 10g R2 Client 32-bit (10.2)
    - 10.2.0.4 - Oracle 32-bit client 10.2.0.4 required for both 32-bit and 64-bit Oracle databases
Application Publishing Products
  • Citrix Presentation Server 4.0
  • Citrix Presentation Server 4.5

Enterprise Client


Operating Systems
  • Windows Vista 32-bit
    - Business - SP1
  • Windows XP 32-bit
    - SP3
Database Platforms
  • Microsoft SQL Server 2005 Client
    - MS SQL Client not required for clients only running SPP&ID. If installed, SP2 - MDAC 2.8 required for MSSQL 2005 databases.
  • Oracle 10g R2 Client 32-bit (10.2)
    - 10.2.0.4 - Oracle 32-bit client 10.2.0.4 required for both 32-bit and 64-bit Oracle databases

Networks


  • Internet Protocol version 4 (IPv4)

Licensing


  • SPLM 2008 (10.00) or later
    - 10.00.05.00 or later
    NOTE: As of December 31, 2024, Hexagon ALI will no longer deliver SPLM keys, and customers must upgrade to the new ALI licensing system, ISL (Intergraph Smart Licensing).

Prerequisites


  • .NET Framework 2.0
  • Adobe Acrobat
    - 8.0 or later
  • Internet Explorer
    - 7.0

Optional Products


  • AutoCAD
    - 2000 or 2002 - used for Save As
  • Microsoft Excel
    - 2003 or 2007 - used for report generation, importing reports, importing SmartSketch, and saving drawings as Microstation or AutoCAD
  • MicroStation J
    - used for Save As
  • SmartPlant Engineering Manager
    - 2009 - used for Administrative functions
  • SmartSketch
    - 2007.5 (05.02.05.07) - used for editing border files or importing SmartSketch files
  • SP3D Piping Specification Remote Access Client
    - 01.00.00.00 - Compatible with all SP3D 2007 and 2009 versions - used for communicating with the Piping Specification utility in SmartPlant 3D
  • Visual Basic
    - 6.0 or .Net - used for automation

Notes


  • Compatible with SP-Electrical 2009
  • For SPFoundation see SmartPlant Foundation Interoperability below or see the SPFoundation compatibility matrix for more information.

Smart P&ID (06.00.00.32 (2009)) is Used in Tool Groups


-- END OF REPORT --